Transmission method
Baudrate
Power supply voltage
Power consumption
Insulation voltage

‧For DVP-EH2-L, DVP-SX2 and DVP-SV series PLC only
‧Supports Modbus TCP protocol
‧Max. baudrate: 100M bps
‧Modbus TCP connections
    Client: 32
    Server: 16
‧Smart data exchange
‧RTU mapping
‧Simple firewall
‧E-mail alarm

 

Specifications

‧Transmission method: IEEE 802.3, IEEE 802.3u
‧Transmission interface: RJ-45 MDI/MDIX, no jumper cable required
‧Baudrate: 10/100 Mbps, auto-detection
‧Network protocols: ICMP, IP, TCP, UDP, DHCP, SMTP, NTP, Modbus TCP
‧Power supply voltage: 24 VDC (-15 to 20%)
‧Power consumption: 1.5 W
‧Insulation voltage: 500 V




  • IEEE 802.3, IEEE 802.3u
  • 10/100 Mbps, auto-detection
  • 24 VDC (-15 to 20%)
  • 1.5 W
  • 500 V

Ethernet

Transmission method
Baudrate
Power supply voltage
Power consumption
Insulation voltage

‧A Modbus TCP slave
‧Connectable to 8 DVP-S series analog I/O modules
‧Connectable to 256 points of digital I/O modules
‧The RS-485 port is connectable to max. 32 Modbus slaves
‧Smart PLC if-then function
‧Smart Monitor
‧Supports webpage setup & on-line monitoring
‧Serial Virtual COM available

Specifications

 

Network Interface:
‧Transmission method: IEEE 802.3, IEEE 802.3u
‧Transmission interface: RJ-45 MDI/MDIX, no jumper cable required
‧Baudrate: 10/100M bps, auto-detection
‧Network protocols: ICMP, IP, TCP, UDP, DHCP, NTP, Modbus TCP, HTTP
‧Power supply voltage: 24 VDC (-15 to 20%)
‧Power consumption: 2 W
‧Insulation voltage: 500 V
RS-485 Interface:
‧Transmission method: RS-485
‧Connector: Removable
‧Serial baudrate: 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bps
‧Data type: Modbus ASCII/RTU

  • IEEE 802.3, IEEE 802.3u
  • 10/100M bps, auto-detection
  • 24 VDC (-15 to 20%)
  • 2 W
  • 500 V

Ethernet

Transmission method
Baudrate
Power supply voltage
Power consumption
Insulation voltage

‧Isolation in RS-485 channel (incl. power supply)
‧Supports Modbus TCP protocol
‧Smart Monitor
‧Supports webpage setup & on-line monitoring
‧Serial Virtual COM available
‧3 e-mail alarms (DI)

 

Specifications

Network Interface:
‧Transmission method: IEEE 802.3, IEEE 802.3u
‧Transmission interface: RJ-45 MDI/MDIX, no jumper cable required
‧Baudrate: 10/100M bps, auto-detection
‧Network protocols: ICMP, IP, TCP, UDP, DHCP, SMTP, Modbus TCP
‧Power supply voltage: 24 VDC (-15 to 20%)
‧Power consumption: 3 W
‧Insulation voltage: 500 V
RS-485 Interface:
‧Connector 1: RJ-11, 10-pin feed through terminal
‧Connector 2: 3-pin, removable
‧Transmission method: RS-485
‧Serial baudrate: 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bps
‧Data type: Modbus ASCII/RTU, user-defined




  • IEEE 802.3, IEEE 802.3u
  • 10/100M bps, auto-detection
  • 24 VDC (-15 to 20%)
  • 3 W
  • 500 V