Arad Automation

DeviceNet

Interesting to know

The beginnings of automation can be traced back to the industrial revolution in the eighteenth century, when people began to use machines to replace human labor and animal power. Read more...

DeviceNet

Transmission method
Serial baudrate
Network voltage
Connector
Message type

‧Supports DeviceNet protocol
‧For DVP-S series PLC only
‧Max. baudrate: 500k bps

Specifications

‧Transmission method: CAN
‧Connector: Removable, 5.08mm
‧Message type: Explicit, I/O polled
‧Serial baudrate: 125k, 250k, 500k bps
‧Network voltage: 24 VDC (11 to 25 VDC)
‧Electrical isolation: 500 VDC


  • CAN
  • 125k, 250k, 500k bps
  • 24 VDC (11 to 25 VDC)
  • Removable, 5.08mm
  • Explicit, I/O polled

DeviceNet

Transmission method
Serial baudrate
Network voltage
Connector
Message type

‧Supports DeviceNet protocol
‧Connectable to 8 DVP-S series analog I/O modules
‧Connectable to 256 points of digital I/O modules
‧The RS-485 port is connectable to max. 8 Modbus slaves
‧Max. baudrate: 500k bps

 

Specifications

‧Transmission method: CAN
‧Connector: Removable, 5.08mm
‧Message type: Explicit, I/O polled
‧Serial baudrate: 125, 250, 500k bps
‧Network voltage: 24 VDC (11 to 25 VDC)


  • CAN
  • 125, 250, 500k bps
  • 24 VDC (11 to 25 VDC)
  • Removable, 5.08mm
  • Explicit, I/O polled

DeviceNet

Transmission method
Serial baudrate
Network voltage
Connector
Message type

‧Supports DeviceNet protocol
‧Connectable to all Delta’s industrial automation products
‧Isolation in DeviceNet channel (incl. power supply)
‧Passed full compatibility test

 

Specifications

‧Transmission method: CAN
‧Electrical isolation: 500 VDC
‧Connector: Removable, 5.08mm
‧Transmission cables: 2 communication cables, 2 power cables, 1 shielded cable
‧Serial baudrate: 125, 250, 500k bps
‧Network voltage: 24 VDC (11 to 25 VDC)
‧Current: 28 mA (typical), 125 mA impulse current (24 VDC)


  • CAN
  • 125, 250, 500k bps
  • 24 VDC (11 to 25 VDC)
  • Removable, 5.08mm
  • Explicit, I/O polled

DeviceNet

Transmission method
Serial baudrate
Network voltage
Connector
Message type

‧Supports DeviceNet protocol
‧For DVP-EH2 series PLC only
‧Max. baudrate: 500k bps

 

Specifications

‧Transmission method: CAN
‧Connector: Removable, 5.08mm
‧Message type: Explicit, I/O polled
‧Serial baudrate: 125k, 250k, 500k bps
‧Network voltage: 24 VDC (11 to 25VDC)
‧Electrical isolation: 500 VDC


  • CAN
  • 125k, 250k, 500k bps
  • 24 VDC (11 to 25VDC)
  • Removable, 5.08mm
  • Explicit, I/O polled

Copyright © Arad Automation Corporation 2002-2014. All rights reserved.