Arad Automation

PROFIBUS

Interesting to know

The beginnings of automation can be traced back to the industrial revolution in the eighteenth century, when people began to use machines to replace human labor and animal power. Read more...

PROFIBUS

Transmission method
Connector
Serial baudrate
Message type
Power supply voltage

‧A PROFIBUS DP slave module for DVP-S series PLC only
‧Supports PROFIBUS DP protocol
‧Max. baudrate: 12M bps
‧With RS-485 port, connectable to max. 16 devices

 

Specifications

‧Transmission method: High-speed RS-485
‧Connector: DB9
‧Serial baudrate: 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M bps
‧Message type: DPV0
‧Power supply voltage: 24 VDC (-15 to 20%)


  • High-speed RS-485
  • DB9
  • 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M bps
  • DPV0
  • 24 VDC (-15 to 20%)

PROFIBUS

Transmission method
Connector
Serial baudrate
Message type
Power supply voltage

‧A PROFIBUS DP slave module for DVP-EH2 series PLC only
‧Supports PROFIBUS DP protocol
‧Max. baudrate: 12M bps

 

Specifications

‧Transmission method: High-speed RS-485
‧Connector: DB9
‧Serial baudrate: 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M bps
‧Message type: DPV0
‧Power supply voltage: 24 VDC (-15 to 20%)


  • High-speed RS-485
  • DB9
  • 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M bps
  • DPV0
  • 24 VDC (-15 to 20%)

PROFIBUS

Transmission method
Connector
Serial baudrate
Message type
Power supply voltage

‧A Left-side high-speed PROFIBUS DP slave module for DVP-S series PLC only.
‧Supports PROFIBUS DP protocol
‧Auto detection for transmission speed. Max. baudrate: 12Mbps
‧Supports cyclic data transmission between master module.
‧Data transmission: supports up to 100 words of I/O inputs and 100 words of I/O outputs

 

Specifications

‧Transmission method: High-speed RS-485
‧Connector: D-SUB 9
‧Serial baudrate: 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M bps
‧Message type: DPV0
‧Power supply voltage: 24 VDC (-15 to 20%)


  • High-speed RS-485
  • D-SUB 9
  • 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M bps
  • DPV0
  • 24 VDC (-15 to 20%)

PROFIBUS

Transmission method
Connector
Serial baudrate
Message type
Power supply voltage

‧A PROFIBUS DP remote communication module
‧Supports PROFIBUS DPV0 cyclic data transmission
‧Auto-detects baudrate, diagnosis
‧Max. baudrate: 12M bps
‧Connectable to 8 DVP-S series analog I/O modules
‧Connectable to 256 points of digital I/O modules
‧RS-485 port is connectable to max. 16 Modbus slaves
‧Supports max. 100 bytes of I/O data input and 100 bytes of output

 

Specifications

‧Transmission method: High-speed RS-485
‧Connector: DB9
‧Serial baudrate: 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M bps
‧Message type: DPV0
‧Power supply voltage: 24 VDC (-15 to 20%)
‧Power consumption: 2.5 W
‧Insulation voltage: 500 VDC


  • High-speed RS-485
  • DB9
  • 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M bps
  • DPV0
  • 24 VDC (-15 to 20%)