Arad Automation

Industrial Fieldbus Solutions

Ethernet

Ethernet

‧Combines the most popular Ethernet and industrial products
‧Crosses the boundary of traditional types of transmissions
‧Offers 10/100M bps high-speed transmission and highly efficient monitoring

View items...

DeviceNet

DeviceNet

‧Supports connections with products of other brands
‧Wire-saving network topology
‧Offers 500k bps fieldbus data transmission of high stability and high interference resistance
‧Applicable in intricate industrial sites

View items...

CANopen

CANopen

‧Flexible configuration
‧Supports CANopen DS301 and DSP402 protocols
‧Conducts multi-axis, high-speed and intricate motion control by max. baudrate 1M bps

View items...

Modbus Serial

Modbus Serial

‧Supports Modbus serial communication
‧ Offers additional RS-232, RS-422 and RS-485 ports and conversions among channels for various on-site demands

View items...

PROFIBUS

PROFIBUS

‧Supports max. baudrate 12M bps
‧ Applicable for distributed control system in industrial automation

View items...

BACnet

BACnet

Can be easily installed and applied on building automation to lower the cost of system maintenance

View items...

Interesting to know

The beginnings of automation can be traced back to the industrial revolution in the eighteenth century, when people began to use machines to replace human labor and animal power. Read more...

Ethernet

Transmission method
Baudrate
Power supply voltage
Power consumption
Insulation voltage

‧For DVP-EH2-L, DVP-SX2 and DVP-SV series PLC only
‧Supports Modbus TCP protocol
‧Max. baudrate: 100M bps
‧Modbus TCP connections
    Client: 32
    Server: 16
‧Smart data exchange
‧RTU mapping
‧Simple firewall
‧E-mail alarm

 

Specifications

‧Transmission method: IEEE 802.3, IEEE 802.3u
‧Transmission interface: RJ-45 MDI/MDIX, no jumper cable required
‧Baudrate: 10/100 Mbps, auto-detection
‧Network protocols: ICMP, IP, TCP, UDP, DHCP, SMTP, NTP, Modbus TCP
‧Power supply voltage: 24 VDC (-15 to 20%)
‧Power consumption: 1.5 W
‧Insulation voltage: 500 V




  • IEEE 802.3, IEEE 802.3u
  • 10/100 Mbps, auto-detection
  • 24 VDC (-15 to 20%)
  • 1.5 W
  • 500 V

Ethernet

Transmission method
Baudrate
Power supply voltage
Power consumption
Insulation voltage

‧A Modbus TCP slave
‧Connectable to 8 DVP-S series analog I/O modules
‧Connectable to 256 points of digital I/O modules
‧The RS-485 port is connectable to max. 32 Modbus slaves
‧Smart PLC if-then function
‧Smart Monitor
‧Supports webpage setup & on-line monitoring
‧Serial Virtual COM available

Specifications

 

Network Interface:
‧Transmission method: IEEE 802.3, IEEE 802.3u
‧Transmission interface: RJ-45 MDI/MDIX, no jumper cable required
‧Baudrate: 10/100M bps, auto-detection
‧Network protocols: ICMP, IP, TCP, UDP, DHCP, NTP, Modbus TCP, HTTP
‧Power supply voltage: 24 VDC (-15 to 20%)
‧Power consumption: 2 W
‧Insulation voltage: 500 V
RS-485 Interface:
‧Transmission method: RS-485
‧Connector: Removable
‧Serial baudrate: 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bps
‧Data type: Modbus ASCII/RTU

  • IEEE 802.3, IEEE 802.3u
  • 10/100M bps, auto-detection
  • 24 VDC (-15 to 20%)
  • 2 W
  • 500 V

Ethernet

Transmission method
Baudrate
Power supply voltage
Power consumption
Insulation voltage

‧Isolation in RS-485 channel (incl. power supply)
‧Supports Modbus TCP protocol
‧Smart Monitor
‧Supports webpage setup & on-line monitoring
‧Serial Virtual COM available
‧3 e-mail alarms (DI)

 

Specifications

Network Interface:
‧Transmission method: IEEE 802.3, IEEE 802.3u
‧Transmission interface: RJ-45 MDI/MDIX, no jumper cable required
‧Baudrate: 10/100M bps, auto-detection
‧Network protocols: ICMP, IP, TCP, UDP, DHCP, SMTP, Modbus TCP
‧Power supply voltage: 24 VDC (-15 to 20%)
‧Power consumption: 3 W
‧Insulation voltage: 500 V
RS-485 Interface:
‧Connector 1: RJ-11, 10-pin feed through terminal
‧Connector 2: 3-pin, removable
‧Transmission method: RS-485
‧Serial baudrate: 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bps
‧Data type: Modbus ASCII/RTU, user-defined




  • IEEE 802.3, IEEE 802.3u
  • 10/100M bps, auto-detection
  • 24 VDC (-15 to 20%)
  • 3 W
  • 500 V

DeviceNet

Transmission method
Serial baudrate
Network voltage
Connector
Message type

‧Supports DeviceNet protocol
‧For DVP-S series PLC only
‧Max. baudrate: 500k bps

Specifications

‧Transmission method: CAN
‧Connector: Removable, 5.08mm
‧Message type: Explicit, I/O polled
‧Serial baudrate: 125k, 250k, 500k bps
‧Network voltage: 24 VDC (11 to 25 VDC)
‧Electrical isolation: 500 VDC


  • CAN
  • 125k, 250k, 500k bps
  • 24 VDC (11 to 25 VDC)
  • Removable, 5.08mm
  • Explicit, I/O polled

DeviceNet

Transmission method
Serial baudrate
Network voltage
Connector
Message type

‧Supports DeviceNet protocol
‧Connectable to 8 DVP-S series analog I/O modules
‧Connectable to 256 points of digital I/O modules
‧The RS-485 port is connectable to max. 8 Modbus slaves
‧Max. baudrate: 500k bps

 

Specifications

‧Transmission method: CAN
‧Connector: Removable, 5.08mm
‧Message type: Explicit, I/O polled
‧Serial baudrate: 125, 250, 500k bps
‧Network voltage: 24 VDC (11 to 25 VDC)


  • CAN
  • 125, 250, 500k bps
  • 24 VDC (11 to 25 VDC)
  • Removable, 5.08mm
  • Explicit, I/O polled

DeviceNet

Transmission method
Serial baudrate
Network voltage
Connector
Message type

‧Supports DeviceNet protocol
‧Connectable to all Delta’s industrial automation products
‧Isolation in DeviceNet channel (incl. power supply)
‧Passed full compatibility test

 

Specifications

‧Transmission method: CAN
‧Electrical isolation: 500 VDC
‧Connector: Removable, 5.08mm
‧Transmission cables: 2 communication cables, 2 power cables, 1 shielded cable
‧Serial baudrate: 125, 250, 500k bps
‧Network voltage: 24 VDC (11 to 25 VDC)
‧Current: 28 mA (typical), 125 mA impulse current (24 VDC)


  • CAN
  • 125, 250, 500k bps
  • 24 VDC (11 to 25 VDC)
  • Removable, 5.08mm
  • Explicit, I/O polled

DeviceNet

Transmission method
Serial baudrate
Network voltage
Connector
Message type

‧Supports DeviceNet protocol
‧For DVP-EH2 series PLC only
‧Max. baudrate: 500k bps

 

Specifications

‧Transmission method: CAN
‧Connector: Removable, 5.08mm
‧Message type: Explicit, I/O polled
‧Serial baudrate: 125k, 250k, 500k bps
‧Network voltage: 24 VDC (11 to 25VDC)
‧Electrical isolation: 500 VDC


  • CAN
  • 125k, 250k, 500k bps
  • 24 VDC (11 to 25VDC)
  • Removable, 5.08mm
  • Explicit, I/O polled

CANopen

Transmission method
Serial baudrate
Network voltage
Connector
Message type

‧For DVP-EH2-L, DVP-SX2 and DVP-SV series PLC only
‧Supports CANopen protocol
‧Connectable to 110 slaves
‧Max. baudrate: 1M bps
‧Max. network length: 1,000m

 

Specifications

‧Transmission method: CAN
‧Connector: Removable, 5.08mm
‧Serial baudrate: 10k, 20k, 50k, 125k, 250k, 500k, 800k, 1M bps
‧Message type: PDO, SDO, SYNC, Emergency, NMT
‧Power supply voltage: 24 VDC (-15 to 20%)
‧Power consumption: 1.7 W
‧Electrical isolation: 500 VDC


  • CAN
  • 10k, 20k, 50k, 125k, 250k, 500k, 800k, 1M bps
  • *
  • Removable, 5.08mm
  • PDO, SDO, SYNC, Emergency, NMT

CANopen

Transmission method
Serial baudrate
Network voltage
Connector
Message type

‧For DVP-EH2 series PLC only
‧Supports CANopen protocol
‧Max. baudrate: 1M bps

 

Specifications

‧Transmission method: CAN
‧Connector: Removable, 5.08mm
‧Serial baudrate: 10k, 20k, 50k, 125k, 250k, 500k, 800k, 1M bps
‧Message type: PDO, SDO, SYNC, Emergency, NMT
‧Power supply voltage: 24 VDC (-15 to 20%)
‧Power consumption: 1.7 W
‧Electrical isolation: 500 VDC


  • CAN
  • 10k, 20k, 50k, 125k, 250k, 500k, 800k, 1M bps
  • *
  • Removable, 5.08mm
  • PDO, SDO, SYNC, Emergency, NMT

CANopen

Transmission method
Serial baudrate
Network voltage
Connector
Message type

‧Supports CANopen protocol
‧Connectable to all Delta@@s industrial automation products
‧Isolation in CANopen channel (incl. power supply)
‧Passed full compatibility test

 

Specifications

‧Transmission method: CAN
‧Electrical isolation: 500 VDC
‧Connector: Removable, 5.08mm
‧Transmission cables: 2 communication cables, 2 power cables, 1 shielded cable
‧Serial baudrate: 10k, 20k, 50k, 125k, 250k, 500k, 800k, 1M bps
‧Power supply voltage: 24 VDC (-15 to 20%)
‧Current: 28 mA (typical), 125 mA impulse current (24 DC)


  • CAN
  • 10k, 20k, 50k, 125k, 250k, 500k, 800k, 1M bps
  • *
  • Removable, 5.08mm
  • Explicit, I/O polled

CANopen

Transmission method
Serial baudrate
Network voltage
Connector
Message type

‧For DVP-PM series PLC only
‧Complies with CANopen DS301 V4.0.2 Sync, PDO, SDO and NMT
‧Supports 126 asynchronous axes in CANopen DSP402 V2.1 through SDO
‧Supports 4 synchronous axes in CANopen DS402 V2.1
‧Built-in commands to control Delta ASDA-A2 series servo system
‧PLCopen Like Function Block

 

Specifications

Network Interface:
‧Transmission method: IEEE 802.3, IEEE 802.3u
‧Baudrate: 10/100M bps
‧Transmission distance: 100m
CAN Interface:
‧Message type: PDO, SDO, SYNC, Emergency, NMT
‧Connector: Removable, 5.08mm
‧Serial baudrate: 500k, 1M bps
‧Power consumption: 1.7 W
‧Insulation voltage: 500 V


  • IEEE 802.3, IEEE 802.3u
  • 500k, 1M bps
  • *
  • Removable, 5.08mm
  • PDO, SDO, SYNC, Emergency, NMT

Modbus Serial

Transmission method
Baudrate
Connector

‧A serial signal regenerator
‧Extends RS-422/485 transmission to 1.2km
‧Connectable to 32 RS-485 devices
‧Isolation in RS-485 channel (incl. power supply)

 

Specifications

‧Power supply: +9 to +35 VDC
‧Power consumption: 1.6 W
‧Insulation voltage: 3,000 VDC
‧Baudrate: 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bps
‧Terminal: 10-pin, accepts AWG1-#12 to #24 wires
‧Dimensions (L×W×H): 4.80×2.79×0.87in (122mm×71mm×22mm)


  • *
  • 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bps
  • Connectable to 32 RS-485 devices

Modbus Serial

Transmission method
Baudrate
Connector

‧For DVP-EH2 series PLC only
‧A RS-232 communication card
‧As an additional RS-232 port for COM3

 

Specifications

‧Transmission method: RS-232
‧Connector: DB-9
‧Baudrate: 9,600, 19,200, 38,400 bps


  • RS-232
  • 9,600, 19,200, 38,400 bps
  • DB-9

Modbus Serial

Transmission method
Baudrate
Connector

‧Supports Modbus protocol
‧Connectable to 8 DVP-S series analog I/O modules
‧Connectable to 256 points of digital I/O modules
‧Max. baudrate: 115.2k bpsk

 

Specifications

‧Transmission method: RS-485
‧Connector: 3-pin, removable
‧Serial baudrate: 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bps
‧Data type: Modbus ASCII/RTU
‧Power supply voltage: 24 VDC (-15 to 20%)


  • RS-485
  • 1,200, 2,400, 4,800, 9,600, 19,200, 38,400, 57,600, 115,200 bps
  • 3-pin, removable

Modbus Serial

Transmission method
Baudrate
Connector

‧PLC extension module to amplify signals for the left-side communication and support uploading and downloading of PLC program and parameters
‧Provides two stand-alone RS-485/RS-422 ports
‧Supports standard MODBUS protocol
‧Supports user-defined communication protocol
‧Fully isolates communication interfaces and highly capable in resisting interferences

 

Specifications

‧Transmission method: RS-485/RS-422
‧Connector type: Euro-type terminal blocks with feed-through terminals and spring plugs
‧Terminal resistors: built-in and changed-over by switches
‧Serial baudrates: 1,200、2,400、4,800、9,600、19,200、38,400、57,600、115,200、230,400、460,800 bps
‧Data type: Modbus ASCII/RTU、UD Link (user-defined communication protocol)


 

  • RS-485/RS-422
  • 1,200、2,400、4,800、9,600、19,200、38,400、57,600、115,200、230,400、460,800 bps
  • Euro-type terminal blocks with feed-through terminals and spring plugs

PROFIBUS

Transmission method
Connector
Serial baudrate
Message type
Power supply voltage

‧A PROFIBUS DP slave module for DVP-S series PLC only
‧Supports PROFIBUS DP protocol
‧Max. baudrate: 12M bps
‧With RS-485 port, connectable to max. 16 devices

 

Specifications

‧Transmission method: High-speed RS-485
‧Connector: DB9
‧Serial baudrate: 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M bps
‧Message type: DPV0
‧Power supply voltage: 24 VDC (-15 to 20%)


  • High-speed RS-485
  • DB9
  • 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M bps
  • DPV0
  • 24 VDC (-15 to 20%)

PROFIBUS

Transmission method
Connector
Serial baudrate
Message type
Power supply voltage

‧A PROFIBUS DP slave module for DVP-EH2 series PLC only
‧Supports PROFIBUS DP protocol
‧Max. baudrate: 12M bps

 

Specifications

‧Transmission method: High-speed RS-485
‧Connector: DB9
‧Serial baudrate: 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M bps
‧Message type: DPV0
‧Power supply voltage: 24 VDC (-15 to 20%)


  • High-speed RS-485
  • DB9
  • 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M bps
  • DPV0
  • 24 VDC (-15 to 20%)

PROFIBUS

Transmission method
Connector
Serial baudrate
Message type
Power supply voltage

‧A Left-side high-speed PROFIBUS DP slave module for DVP-S series PLC only.
‧Supports PROFIBUS DP protocol
‧Auto detection for transmission speed. Max. baudrate: 12Mbps
‧Supports cyclic data transmission between master module.
‧Data transmission: supports up to 100 words of I/O inputs and 100 words of I/O outputs

 

Specifications

‧Transmission method: High-speed RS-485
‧Connector: D-SUB 9
‧Serial baudrate: 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M bps
‧Message type: DPV0
‧Power supply voltage: 24 VDC (-15 to 20%)


  • High-speed RS-485
  • D-SUB 9
  • 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M bps
  • DPV0
  • 24 VDC (-15 to 20%)

PROFIBUS

Transmission method
Connector
Serial baudrate
Message type
Power supply voltage

‧A PROFIBUS DP remote communication module
‧Supports PROFIBUS DPV0 cyclic data transmission
‧Auto-detects baudrate, diagnosis
‧Max. baudrate: 12M bps
‧Connectable to 8 DVP-S series analog I/O modules
‧Connectable to 256 points of digital I/O modules
‧RS-485 port is connectable to max. 16 Modbus slaves
‧Supports max. 100 bytes of I/O data input and 100 bytes of output

 

Specifications

‧Transmission method: High-speed RS-485
‧Connector: DB9
‧Serial baudrate: 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M bps
‧Message type: DPV0
‧Power supply voltage: 24 VDC (-15 to 20%)
‧Power consumption: 2.5 W
‧Insulation voltage: 500 VDC


  • High-speed RS-485
  • DB9
  • 9.6k, 19.2k, 93.75k, 187.5k, 500k, 1.5M, 3M, 6M, 12M bps
  • DPV0
  • 24 VDC (-15 to 20%)

BACnet

Transmission method
Type
Terminal resistance
Baudrates
Communication protocol

‧Supports BACnet MS/TP slave protocol
‧Easy to be connected and controlled via software of other brands
‧Functions as BACnet MS/TP remote I/O or gateway
‧Supports MODBUS with user-defined protocol
‧High noise immunity
‧High speed module on the left (PLC needed)

 

Specifications

‧Transmission method: RS-485/RS-422
‧Type : Feed-through terminals, with spring plugs
‧Terminal resistance : built in 120 ohm with a switch
‧Baudrates : 1,200、2,400、4,800、9,600、19,200、38,400、57,600、76,800,、115,200、230,400、460,800 bps
‧Communication protocol : BACnet MS/TP Slave、MODBUS ASCII/RTU、UD Link


  • RS-485/RS-422
  • Feed-through terminals, with spring plugs
  • built in 120 ohm with a switch
  • 1,200、2,400、4,800、9,600、19,200、38,400、57,600、76,800,、115,200、230,400、460,800 bps
  • BACnet MS/TP Slave、MODBUS ASCII/RTU、UD Link

Copyright © Arad Automation Corporation 2002-2014. All rights reserved.